Agilent provides xCELLigence impedance-based, label-free, real time cell analysis system and NovoCyte flow cytometers.
Discover
Related topics
Advances in Leukemia research using shear flow and Bioflux system
Feb 3, 2023
Leukemia is a rare cancer with many subtypes. The production of abnormal leukocytes create disruptions in the immune...
Webinar: Dose Reduction and Image Enhancement in Preclinical Mouse Imaging using Deep Learning
Jan 31, 2023
In this webinar, ir. Florence Muller (Ghent University - University of Pennsylvania) is presenting two recent studies...
Advance your Spatial Biology, customize your panel design with RareCyte Orion reagents
Jan 23, 2023
Orion system, the highly multiplexed fluorescent imaging system, in combination with dedicated reagents, empower...
Extensive assessment of Cytokine production on the NovoCyte Advanteon flow cytometer
Jan 13, 2023
Cytokines are small molecules essential for immune cell response to activation by pathogens, autoimmunity, or...
New installation of Cytek Aurora in Slovenia
Jan 11, 2023
2nd spectral flowcytometer Aurora from Cytek was installed at National Institute of Biology in Slovenia
Microfluidic cell sorter sample preparation for genomic assays
Dec 16, 2022
Single-cell RNA-Sequencing has led to many novel discoveries such as the detection of rare cell populations, microbial...
CellRad+ benchtop X-Ray irradiator
Dec 9, 2022
New CellRad+ benchtop irradiator for biological samples is coming with higher voltage and continue exposure for 180...
Dec 1, 2022
Cytek Cloud is the new digital ecosystem that supports full spectrum flow cytometry research from panel design to data...
See More, Sort More with Cytek Full Spectrum Systems
Nov 28, 2022
Still wondering whether to join the shift to full spectrum cytometry? Easily transfer assays from your Cytek Northern...
Demonstrate the value of RareCyte Orion system via web-based Minerva viewer
Nov 25, 2022
The HTA CRC Atlas X dataset contains images and other data being used for construction of an atlas of human colorectal...
Aug 3, 2016
The advantages of using 561nm laser configured NovoCyte flow cytometers include: enhancing fluorescent signals of PE-conjugated antibodies with 561nm excitation and increasing sensitivity on detecting dim signals; eliminating or minimizing FITC to PE spillovers by independent excitation with 488nm and 561nm lasers; favoring the detection of multiple fluorescent proteins such as GFP, DsRed and mCherry; fulfilling multicolor analysis of variety of applications.
PE series of fluorochromes (PE, PE-Texas Red, PE-CF594, PE-Cy5, PE-Cy5.5 and PE-Cy7) have a primary absorption peak of 565nm with secondary absorption peaks at 496 and 545nm that can be excited by either the 488nm or 561nm lasers. However, higher excitation efficiency of 561nm laser results in brighter fluorescence signals and detection sensitivity, manifested by improved stain index and separation of positive from negative populations.
Related technologies: Conventional flow cytometry
Brand profile
Agilent provides xCELLigence impedance-based, label-free, real time cell analysis system and NovoCyte flow cytometers.